If Pump is Jam Condition fill hot water from Valve (A) and Rotate by hand
Close Ball Valve (B) at suction pipe before Motor off and fill water from
top delivery side Valve (A) so that pump is filled in water easy for next motor
start.
Silicate inside the pump do not allow to be dry
keep pump always as wet condition. So fill water inside the pump from top.
Note
:
Make it sure suction pipe is not blocked every Caustic Soda Lye pumping
operation after fill some water at (A) Tank and start pump S. that pump will be
washed out.
Rotate pump shaft by hand.
Note
:
Make it sure suction pipe is not blocked every Quartz Powder Slurry Lye pumping
operation after fill some water at (A) Tank or from Valve (B) and start pump so
that pump will be washed out. Further keep some water inside so that pump will
be always free not jammed.
Rotate pump shaft by hand before motor starting.
INSTALLATION
OF FILTER PRESS PUMPSET
We enclose herewith a line sketch (Installation drawing) for piping work
to be carried out by you for Filter Press Pump.
Do this Plumbing as per sketch.
5% Water can be returned through Gate Valve ‘B’ for
mixing the sludge in the collection tank.
Do not operate Motor with Valve ‘B’ Fully open.
Before Motor Start Gate Valve ‘A’ and Gate Valve ‘B’
Must be close.
Condition and fill water through Ball
Valve ‘C’ and remove Air and start the Motor then slowly open the
Gate Valve ‘A’ let continuously pumping directly into Filter
press atleast 30 Minute then open Valve ‘B’ partially and allow
5% water to be returned to suction tank. (near
suction pipe) for mixing the sludge.